ALM0056 - HCI/CTI/TAPI Monitor Allowed

Expand / Collapse
 

ALM0056 - HCI/CTI/TAPI Monitor Allowed


Article ID: 51502 - Last Review: April 27th, 2012

DESCRIPTION

HCI/CTI/TAPI Monitor is not enabled in the Class of Service (COS) on the PBX.



SEVERITY

Minor



IMPACT

HCI/CTI/TAPI Monitor needs to be enabled in the COSA on the PBX in order to use Contact Center Screenpop, UPiQ, Interactive Contact Center, and Intelligent Queue.

TROUBLESHOOTING STEPS

Mitel - Select "Yes" to permit the user's station to be controlled by the host computer

1. Open the 3300 ESM.
2. On the left click on System Properties => System Feature Settings => Class of Service Options.
3. Click the Class of Service that threw the alarm, and click the Change button at the top.
4. Scroll down to HCI/CTI/TAPI Monitor Allowed and set it to Yes.
5. Click Save.

NOTE: This alarm will need to be cleared manually by going to YourSite Explorer and clicking on Alarms.  Select the alarm in question and click the Snooze button.

APPLIES TO

6.0 SP1

Keywords: HCI/CTI/TAPI HCI\CTI\TAPI Call Controll