VWM0020 - IVR Node is missing

Expand / Collapse
 

VWM0020 - IVR Node is missing


Article ID: 51627 - Last Review: December 1, 2015

DESCRIPTION

The VWM Node is not appearing in the SQL configuration. 



SEVERITY

Major 



IMPACT

VWM records can not be filed.  VWM will not function properly. 



TROUBLESHOOTING STEPS

1. Re-run the CCM Configuration Wizard.
2. Open SQL Management Studio.
3. Open the CCMData database.
4. Verify that the tblEnterpriseConfig_Node table is populated with a node entry for VWM.



APPLIES TO

CCM / VWM 6.0 SP1 

Keywords: VWM0020 VWM Node missing SQL



Rate this Article:
     